Case
The company focuses on the development of aircraft ground air-conditioning units by virtue of refrigeration electrical control technology and in-depth research on the needs of users
SF-130X aircraft ground air conditioning unit (floor-standing)

Aircraft Ground Air Conditioning Unit
Aircraft ground air conditioning units are ground support equipment that provide a certain flow rate, pressure, and temperature of ventilation air to aircraft while they are parked on the ground. This air is used for air conditioning for crew and passengers after boarding the aircraft.
Standards and Norms:
The product is designed and manufactured strictly in accordance with the MH-T6109-2014 standard for "Aircraft Ground Air Conditioning Units".
Operating Conditions:
T1 Condition: Ambient dry-bulb temperature 35℃, relative humidity 50%;
T2 Condition: Ambient dry-bulb temperature 35℃, relative humidity 60%;
T3 Condition: Ambient dry-bulb temperature 35℃, relative humidity 70%;
T4 Condition: Ambient dry-bulb temperature 35℃, relative humidity 80%;
Product Technical Features:
Rapid Cooling. In cooling mode, the outlet temperature drops to below 3℃ within 3 minutes, effectively meeting the air conditioning cooling requirements of short-stop flights.
Ultra-Low Temperature Air Supply. In cooling mode, the air supply temperature remains stable below 2℃ during non-defrosting periods.
Intelligent Defrosting Function. During defrosting, the unit operates stably, and the outlet temperature does not exceed 5℃; each defrosting takes no more than 4 minutes; the defrosting cycle exceeds 1 hour; and defrosting energy consumption is low.
Wide Operating Range Design. Each unit can simultaneously meet the four operating conditions T1, T2, T3, and T4. Operating temperature range -40℃~52℃, relative humidity range 0-100%.
Suitable for All Aircraft Models. Reasonable configuration of the unit can meet the cooling (and heating) requirements of all aircraft models (including A380 super-large passenger aircraft).
Easy Maintenance. Modular system design, easy to replace parts; good parts commonality, few spare parts types.
Mobile APP Intelligent Monitoring. A mobile APP is available for users to view the unit's operating status and fault alarms at any time, reducing ineffective equipment inspections, improving maintenance efficiency, and saving maintenance costs.
Technical Parameters:
| Project Description | Technical Parameters |
| Climate Type | T1/T2/T3/T4 |
| Installation Method | Floor-standing |
| Power Supply | AC380V 3N.50HZ |
| Compressor Type | Scroll Type |
| Number of Compressors | 8Ea |
| Refrigerant Type and Charge Amount | R410A/131kg |
| Airflow | 4500m3 /h~12000m 3 /h Adjustable |
| Cooling Capacity | 102kw~368kw |
| External Static Pressure | 4200Pa~7350Pa Adjustable |
| Electric Heating Power | 100kw~150kw |
| Cooling Input Power | <200kw |
| Centrifugal Fan Power | 30*2kw |
| Noise | ≤85db(A) |
| Cooling Air Outlet Dry-Bulb Temperature | -5~5℃ |
| Dimensions (L*W*H) | 5600*2450*1830mm |
| Operating Weight | 4450kg |
Note: 1. Technical parameters are subject to the product nameplate and can be customized according to user needs. Due to continuous product improvement, technical parameters are subject to change without notice.
2. Refrigerants R134A, R407A, and R410A can be used according to user requirements.
Product Installation Dimension Diagram:

SF-130X Installation Dimension Diagram
Company Product Patents:
|
Aircraft Ground Air Conditioning Unit (Patent Authorization No.: ZL201630132533.5); |
A kind of installation structure of aircraft ground air conditioning unit (Patent Authorization No.: ZL201620330337.3); |
|
A kind of air filter device for aircraft ground air conditioning unit (Patent Authorization No.: ZL201620330077.X); |
A kind of soft connection structure of aircraft ground air conditioning unit (Patent Authorization No.: ZL201620331194.8); |
|
A kind of air valve assembly (Patent Authorization No.: ZL201620334261.1); |
A kind of evaporator air distribution device (Patent Authorization No.: ZL201620331051.7); |
|
A kind of evaporator water tank installation assembly for aircraft ground air conditioning unit (Patent Authorization No.: ZL201721516063.8); |
A kind of centrifugal fan assembly for aircraft ground air conditioning unit (Patent Authorization No.: ZL201721516065.7); |
|
A kind of air intake device for aircraft ground air conditioning unit (Patent Authorization No.: ZL201821021482.9); |
A mobile evaporative core for aircraft ground air conditioning (Patent Authorization No.: ZL201821023533.1); |
|
An anti-collision device for a bridge-mounted aircraft ground air conditioning unit (Patent Authorization No.: ZL201821022602.7); |
A squirrel-cage type condenser core for aircraft ground air conditioning unit (Patent Authorization No.: ZL202021182796.4); |
|
A device for preventing backflow and air intake for aircraft ground air conditioning units (Patent Authorization No.: ZL202021183789.6); |
Applicable Models: